71-212-4MG6
Circuit Breakers
CIRCUIT BREAKER
71-212-4MG6
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Switch Terminal Typetab, solder lug 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.750 inches nominal 
- 
                                    Trip Release Characteristicinstantaneous all locations 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts208.0 ac all locations 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Pole Quantity2 
- 
                                    Maximum Continuous Load Current Rating Per Pole28.0 amperes ac all locations 
- 
                                    Thread Series Designatorunc 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Switch Current Rating And Type In Amps5.0 ac and 1.0 dc 
- 
                                    Switch Location And Position Designationinternal at pole two 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Mounting Surface To Terminal End Distance2.549 inches minimum and 2.673 inches maximum 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Switch Voltage Rating And Type In Volts125.0 ac and 50.0 dc 
- 
                                    Mounting Facility Type And Quantity4 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Unpackaged Unit Weight0.547 pounds 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and moisture resistant 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.750 inches nominal 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Body Length2.500 inches nominal 
- 
                                    Boss Height0.140 inches nominal 
- 
                                    Frequency In Hertz50.0 all locations or 60.0 all locations 
- 
                                    Manual Actuator Type And Quantity2 toggle 
- 
                                    Auxiliary Switch Function And Quantity1 alarm 
- 
                                    Terminal Type And Quantity4 threaded stud 
- 
                                    Body Width1.500 inches nominal 
- 
                                    External Actuator Linkage Arrangementone and two linked 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.938 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.062 inches nominal 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    