Technical Characteristics
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Manual Actuator Type And Quantity1 push-pull 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant 
- 
                                    Mounting Surface To Terminal End Distance1.812 inches nominal 
- 
                                    Pole Quantity1 
- 
                                    Body Length1.062 inches nominal 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts115.0 ac single location and 28.0 dc single location 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Bushing Length0.375 inches nominal 
- 
                                    Frequency In Hertz400.0 single location 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.656 inches nominal 
- 
                                    Body Stylesingle pole type 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 ac single location and 2000.0 dc single location 
- 
                                    Trip Release Characteristicinstantaneous single location 
- 
                                    Nominal Thread Size0.469 inches 
- 
                                    Thread Series Designatoruns 
- 
                                    Case Materialplastic 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent130.0 single location 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Maximum Continuous Load Current Rating Per Pole25.0 amperes ac single location and 25.0 amperes dc single location 
- 
                                    Body Width0.750 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Terminal Type And Quantity2 screw 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Methodthermal single location 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    