AP12-789-1
Circuit Breakers
CIRCUIT BREAKER
AP12-789-1
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Pole Quantity2 
- 
                                    Reset Methodmanual 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing w/panel seal 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.625 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps500.0 ac all locations 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Mounting Surface To Terminal End Distance1.780 inches maximum 
- 
                                    Inclosure Protection Type For Which Designedhermetically sealed 
- 
                                    Terminal Type And Quantity4 wire hook 
- 
                                    Maximum Continuous Load Current Rating Per Pole3.0 amperes ac all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.875 inches nominal 
- 
                                    Bushing Length0.375 inches maximum 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Case Materialmetal 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Body Length1.500 inches maximum 
- 
                                    Actuator Position Designationbetween pole one and two 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 all locations 
- 
                                    Boss Height1.780 inches maximum 
- 
                                    Body Width1.250 inches maximum 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Thread Series Designatorunef 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts120.0 ac all locations 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.200 minimum at 200 pct all locations and 6.000 maximum at 200 pct all locations 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    