Technical Characteristics
- 
                                    Case Materialmetal 
- 
                                    Internal Trip Release Configurationseries trip second location 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip third location 
- 
                                    Body Width1.937 inches maximum 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Switch Current Rating And Type In Amps0.5 ac and 0.5 dc 
- 
                                    Body Length1.562 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.906 inches maximum 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.008 minimum at 200 pct all locations and 0.300 maximum at 200 pct all locations 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Thread Series Designatorunef 
- 
                                    Switch Voltage Rating And Type In Volts120.0 ac and 50.0 dc 
- 
                                    Maximum Continuous Load Current Rating Per Pole15.0 amperes ac third location 
- 
                                    Maximum Continuous Load Current Rating Per Pole7.5 amperes ac second location 
- 
                                    Internal Trip Release Configurationrelay trip first location 
- 
                                    Auxiliary Switch Function And Quantity1 control 
- 
                                    Switch Terminal Typetab, solder lug 
- 
                                    Bushing Length0.380 inches nominal 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole10.0 amperes ac first location 
- 
                                    Reset Methodmanual 
- 
                                    Switch Location And Position Designationinternal at pole three 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.625 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Mounting Surface To Terminal End Distance1.828 inches maximum 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Thread Pitch Diameters+0.3503/+0.3537 inches 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac all locations 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Inclosure Protection Type For Which Designedhermetically sealed 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Terminal Type And Quantity8 wire hook 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    