7855-7-175
Circuit Breakers
CIRCUIT BREAKER
7855-7-175
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Style18a single pole type 
- 
                                    Body Width2.125 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.500 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length3.500 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.000 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance2.219 inches nominal 
- 
                                    Mounting Facility Type And Quantity4 threaded hole 
- 
                                    Maximum Continuous Load Current Rating Per Pole175.0 amperes dc single location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps3000.0 dc single location 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent130.0 single location 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Trip Release Ambient Temp Rating77.0 deg fahrenheit nominal single location 
- 
                                    Overall Length4.000 inches nominal 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Pole Quantity1 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts30.0 dc single location 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Reset Methodautomatic 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Nominal Thread Size0.190 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current2.700 minimum at 200 pct single location and 6.000 maximum at 200 pct 
- 
                                    Thread Series Designatorunf 
- 
                                    Terminal Type And Quantity2 threaded stud 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    