AP112R1918-19
Circuit Breakers
CIRCUIT BREAKER
AP112R1918-19
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Length1.500 inches maximum 
- 
                                    Body Width1.875 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.625 inches nominal 
- 
                                    Nonturn Device Diameter0.245 inches minimum and 0.255 inches maximum 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Mounting Surface To Terminal End Distance1.780 inches maximum 
- 
                                    Pole Quantity3 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes dc third location 
- 
                                    Maximum Continuous Load Current Rating Per Pole7.0 amperes dc first location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts50.0 dc all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps500.0 dc all locations 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Position Designationbetween pole one and two 
- 
                                    Auxiliary Switch Function And Quantity1 alarm 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.070 minimum at 200 pct all locations and 0.700 maximum at 200 pct 
- 
                                    Inclosure Protection Type For Which Designedhermetically sealed and shockproof and vibrationproof 
- 
                                    Switch Current Rating And Type In Amps0.5 ac and 0.5 dc 
- 
                                    Unpackaged Unit Weight5.400 ounces 
- 
                                    Thread Series Designatorunef 
- 
                                    Terminal Type And Quantity6 wire hook 
- 
                                    Thread Pitch Diameters0.3503 to 0.3537 inches 
- 
                                    Body Style1b multipole-single actuator type 
- 
                                    Bushing Length0.380 inches maximum 
- 
                                    Case Materialmetal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.875 inches nominal 
- 
                                    Nonturn Device Radius0.620 inches minimum and 0.630 inches maximum 
- 
                                    Nonturn Device Length0.135 inches minimum and 0.145 inches maximum 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing w/panel seal 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Maximum Continuous Load Current Rating Per Pole3.0 amperes dc second location 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Switch Location And Position Designationinternal at pole one 
- 
                                    Switch Terminal Typetab, solder lug 
- 
                                    Switch Voltage Rating And Type In Volts120.0 ac and 50.0 dc 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    