DMS 80042B
Circuit Breakers
CIRCUIT BREAKER
DMS 80042B
Defense Electronics Supply Center
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Terminal Type And Quantity2 wire hook 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.687 inches nominal 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Ultimate Trip Time Per Pole In Seconds0.035 nominal single location 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Pole Quantity1 
- 
                                    Case Materialmetal 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Switch Location And Position Designationexternal at pole one 
- 
                                    Trip Release Methodthermal-magnetic single location 
- 
                                    Thread Series Designatorunef 
- 
                                    Switch Voltage Rating And Type In Volts120.0 ac and 50.0 dc 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps500.0 dc single location 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts50.0 dc single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Switch Terminal Typeeyelet 
- 
                                    Auxiliary Switch Function And Quantity1 alarm 
- 
                                    Body Length1.750 inches maximum 
- 
                                    Trip Release Characteristicinstantaneous single location 
- 
                                    Mounting Surface To Terminal End Distance1.635 inches nominal 
- 
                                    Inclosure Protection Type For Which Designedshockproof and vibrationproof and hermetically sealed 
- 
                                    Bushing Length0.315 inches nominal 
- 
                                    Maximum Continuous Load Current Rating Per Pole1.5 amperes dc single location 
- 
                                    Switch Current Rating And Type In Amps1.0 ac and 0.5 dc 
- 
                                    Body Width0.625 inches maximum 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 single location 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    