Technical Characteristics
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.750 inches nominal 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Thread Series Designatorunc 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    External Actuator Linkage Arrangementone, two, and three linked 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Mounting Facility Type And Quantity6 threaded hole 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Body Width2.250 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance2.471 inches nominal 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.750 inches nominal 
- 
                                    Body Length2.500 inches nominal 
- 
                                    Boss Height0.140 inches nominal 
- 
                                    Ultimate Trip Time Per Pole In Seconds7.000 maximum all locations 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole2.0 amperes ac all locations 
- 
                                    Manual Actuator Type And Quantity3 toggle 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.938 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.062 inches nominal 
- 
                                    Terminal Type And Quantity6 threaded stud 
- 
                                    ~1and 0.300 maximum at 300 pct all locations and 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.110 minimum at 300 pct all locations and 0.300 minimum at 200 pct all locations and 7.000 maximum at 125 pct all locations and 3.000 maximum at 150 pct all locations and 0.900 minimum at 150 pct all locations and 1.000 maximum at 200 pct all locations 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    