6049-1046
Circuit Breakers
CIRCUIT BREAKER
6049-1046
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Length2.500 inches nominal 
- 
                                    Body Width1.500 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.938 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.750 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.062 inches nominal 
- 
                                    Boss Height0.140 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance2.471 inches nominal 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts125.0 ac all locations 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current1.500 minimum at 125 pct all locations and 5.000 maximum at 125 pct and 0.600 minimum at 150 pct and 2.500 maximum at 150 pct and 0.250 minimum at 200 pct and 0.900 maximum at 200 pct and 0.100 minimum at 300 pct and 0.300 maximum at 300 pct 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Terminal Type And Quantity4 threaded stud 
- 
                                    Body Style8c multipole-multiple actuator type 
- 
                                    Case Materialplastic 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.750 inches nominal 
- 
                                    Pole Quantity2 
- 
                                    Mounting Facility Type And Quantity4 threaded hole 
- 
                                    Features Providedsliding bar interlock 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Continuous Load Current Rating Per Pole2.3 amperes ac all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 ac all locations 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Ultimate Trip Time Per Pole In Seconds5.000 nominal all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity2 toggle 
- 
                                    External Actuator Linkage Arrangementtwo, three, four, five, and six linked 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Special Featurespoles connected internally 
- 
                                    Thread Series Designatorunc 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    