260-4019-380
Circuit Breakers
CIRCUIT BREAKER
260-4019-380
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current3.000 minimum at 200 pct single location and 9.000 maximum at 200 pct single location and 0.400 minimum at 400 pct single location and 0.800 minimum at 300 pct single location and 2.500 maximum at 300 pct single location and 1.000 maximum at 400 pct 
- 
                                    ~1single location 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Switch Terminal Typetab, solder lug 
- 
                                    Thread Series Designatorunc 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac single location 
- 
                                    Reset Methodmanual 
- 
                                    Mounting Surface To Terminal End Distance2.461 inches minimum and 2.481 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.928 inches minimum and 1.948 inches maximum 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac single location 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Body Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac single location 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Switch Current Rating And Type In Amps2.5 ac and 1.0 dc 
- 
                                    Switch Voltage Rating And Type In Volts250.0 ac and 50.0 dc 
- 
                                    Pole Quantity1 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Frequency In Hertz400.0 single location 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.052 inches minimum and 2.072 inches maximum 
- 
                                    Body Stylesingle pole type 
- 
                                    Trip Release Methodmagnetic-hydraulic single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 single location 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and explosion resistant and moisture resistant 
- 
                                    Ultimate Trip Time Per Pole In Seconds7.000 minimum all locations 
- 
                                    Auxiliary Switch Function And Quantity1 alarm 
- 
                                    Body Length2.490 inches minimum and 2.510 inches maximum 
- 
                                    Boss Height0.130 inches minimum and 0.150 inches maximum 
- 
                                    Switch Location And Position Designationinternal at pole one 
- 
                                    Case Materialplastic 
- 
                                    Terminal Type And Quantity2 threaded stud 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    