840069-2-23
Circuit Breakers
CIRCUIT BREAKER
840069-2-23
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Frequency In Hertz420.0 all locations 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.625 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Mounting Surface To Terminal End Distance1.780 inches maximum 
- 
                                    Test Data Document80249-840069 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Pole Quantity2 
- 
                                    Reset Methodmanual 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing w/panel seal 
- 
                                    Terminal Type And Quantity4 wire hook 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.875 inches nominal 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Inclosure Protection Type For Which Designedhermetically sealed and shockproof and vibrationproof 
- 
                                    Case Materialmetal 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Body Length1.500 inches maximum 
- 
                                    Actuator Position Designationbetween pole one and two 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole10.0 amperes ac all locations and 10.0 amperes dc all locations 
- 
                                    Body Width1.250 inches maximum 
- 
                                    Thread Series Designatorunef 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.070 minimum at 200 pct all locations and 0.700 maximum at 200 pct all locations 
- 
                                    Bushing Length0.332 inches minimum and 0.375 inches maximum 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps300.0 ac all locations 
- 
                                    Unpackaged Unit Weight4.000 ounces 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts120.0 ac all locations and 150.0 dc all locations 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    