MILC39019-1
Circuit Breakers
CIRCUIT BREAKER
MILC39019-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    ~1data on certain environmental and performanc 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.500 minimum at 200 pct single location and 9.000 maximum at 200 pct single location and 1.750 maximum at 400 pct single location 
- 
                                    Ultimate Trip Time Per Pole In Seconds3.000 minimum single location and 60.000 maximum single location 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and hermetically sealed 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Terminal Type And Quantity2 wire hook 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac single location 
- 
                                    Trip Release Methodmagnetic single location 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Pole Quantity1 
- 
                                    Case Materialmetal 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps300.0 ac single location 
- 
                                    Maximum Continuous Load Current Rating Per Pole20.0 amperes ac single location 
- 
                                    Body Length1.562 inches maximum 
- 
                                    Frequency In Hertz400.0 single location 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.906 inches maximum 
- 
                                    Body Stylesingle pole type 
- 
                                    Body Width0.625 inches maximum 
- 
                                    Thread Series Designatorunef 
- 
                                    Mounting Surface To Terminal End Distance1.700 inches maximum 
- 
                                    Bushing Length0.380 inches maximum 
- 
                                    Test Data Document81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    