7274-34-3
Circuit Breakers
CIRCUIT BREAKER
7274-34-3
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Body Width
0.750 inches nominal
-
Actuator Function
trip-reset
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location and 3.0 amperes dc single location
-
Precious Material
gold
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location
-
Thread Quantity Per Inch
32
-
Unpackaged Unit Weight
1.000 ounces
-
Circuit Protection Type
overcurrent single location
-
Bushing Length
0.359 inches nominal
-
Trip Release Method
thermal single location
-
Switch Current Rating And Type In Amps
2.0 ac and 3.0 dc
-
Manual Actuator Type And Quantity
1 push-pull
-
Pole Quantity
1
-
Mounting Surface To Terminal End Distance
1.420 inches maximum
-
Case Material
plastic
-
Thread Series Designator
uns
-
Switch Location And Position Designation
internal at pole one
-
Center To Center Distance Between Terminals Parallel To Length
0.593 inches nominal
-
Inclosure Protection Type For Which Designed
fungus resistant and explosion proof
-
Nominal Thread Size
0.469 inches
-
Auxiliary Switch Function And Quantity
1 alarm
-
Terminal Type And Quantity
2 tab w/screw
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location
-
Switch Voltage Rating And Type In Volts
120.0 ac and 30.0 dc
-
Switch Contact Arrangement
single pole, single throw, normally open
-
Body Style
single pole type
-
Frequency In Hertz
400.0 single location
-
Body Length
1.287 inches minimum and 1.317 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Trip Release Characteristic
time delay single location
-
Precious Material And Location
auxiliary terminals gold
-
Internal Trip Release Configuration
series trip single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac single location and 2500.0 dc single location
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods