Technical Characteristics
- 
                                    Actuator Functionreset 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.750 inches nominal 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Nominal Thread Size0.190 inches 
- 
                                    Reset Methodmanual 
- 
                                    Thread Series Designatorunf 
- 
                                    Switch Terminal Typeturret 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    External Actuator Linkage Arrangementone, two, and three linked 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Switch Voltage Rating And Type In Volts115.0 ac 
- 
                                    Maximum Continuous Load Current Rating Per Pole10.0 milliamperes ac all locations 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Inclosure Protection Type For Which Designedhermetically sealed 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 all locations 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Switch Location And Position Designationexternal at pole one 
- 
                                    Body Width2.250 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance2.471 inches nominal 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.750 inches nominal 
- 
                                    Body Length2.500 inches nominal 
- 
                                    Boss Height0.140 inches nominal 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts115.0 ac all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 ac all locations 
- 
                                    Switch Current Rating And Type In Amps3.0 ac and 3.0 dc 
- 
                                    Mounting Facility Type And Quantity3 threaded stud 
- 
                                    Manual Actuator Type And Quantity3 toggle 
- 
                                    Auxiliary Switch Function And Quantity1 control 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current30.000 maximum at 150 pct all locations and 2.000 maximum at 400 pct all locations and 0.040 maximum at 1000 pct all locations 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.938 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.062 inches nominal 
- 
                                    Terminal Type And Quantity6 threaded stud 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    