AM12MG6-38-32VDC4
Circuit Breakers
CIRCUIT BREAKER
AM12MG6-38-32VDC4
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Ultimate Trip Time Per Pole In Seconds18.000 minimum single location and 70.000 maximum single location 
- 
                                    Boss Height0.125 inches nominal 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps3000.0 dc single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts32.0 dc single location 
- 
                                    Mounting Surface To Terminal End Distance2.484 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.938 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.062 inches nominal 
- 
                                    Terminal Type And Quantity2 threaded stud 
- 
                                    ~1single location 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Thread Series Designatorunc 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Body Width0.760 inches maximum 
- 
                                    Body Length2.530 inches maximum 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Arc Quenching Methodair 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and moisture resistant 
- 
                                    Pole Quantity1 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Release Methodthermal-magnetic single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Maximum Continuous Load Current Rating Per Pole38.0 amperes dc single location 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current10.000 maximum at 200 pct single location and 4.000 minimum at 200 pct single location and 1.400 minimum at 300 pct single location and 30.000 maximum at 150 pct single location and 10.000 minimum at 150 pct single location and 4.000 maximum at 300 pct 