AP12N4-152-1
Circuit Breakers
CIRCUIT BREAKER
AP12N4-152-1
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Actuator Functionreset 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.620 inches nominal 
- 
                                    Pole Quantity2 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Maximum Continuous Load Current Rating Per Pole1.5 amperes ac all locations 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Mounting Surface To Terminal End Distance1.780 inches maximum 
- 
                                    Terminal Type And Quantity4 wire hook 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Body Length1.500 inches maximum 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.880 inches nominal 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac all locations 
- 
                                    Body Width1.250 inches maximum 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Thread Series Designatorunef 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.007 minimum at 200 pct all locations and 0.025 maximum at 200 pct all locations 
- 
                                    Bushing Length0.330 inches minimum and 0.380 inches maximum 
- 
                                    Case Materialplastic 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    