1411-4-13
Circuit Breakers
CIRCUIT BREAKER
1411-4-13
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Width1.875 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.875 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.625 inches nominal 
- 
                                    Pole Quantity3 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic-hydraulic 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Internal Trip Release Configurationseries trip 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.800 minimum at 200 pct and 4.000 maximum at 200 pct 
- 
                                    Frequency In Hertz60.0 
- 
                                    Unpackaged Unit Weight4.500 ounces 
- 
                                    Terminal Type And Quantity6 wire hook 
- 
                                    Body Length1.500 inches maximum 
- 
                                    Bushing Length0.375 inches maximum 
- 
                                    Case Materialmetal 
- 
                                    Mounting Surface To Terminal End Distance1.780 inches maximum 
- 
                                    Maximum Continuous Load Current Rating Per Pole7.5 amperes ac 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps300.0 ac 
- 
                                    Circuit Protection Typeovercurrent 
- 
                                    Trip Release Characteristictime delay 
- 
                                    Ultimate Trip Time Per Pole In Seconds8.000 minimum and 18.500 maximum 
- 
                                    Reset Methodmanual 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and moisture resistant and hermetically sealed 
- 
                                    Thread Series Designatorunef 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    