M39019-3-49
Circuit Breakers
CIRCUIT BREAKER
M39019-3-49
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Thread Series Designatorunef 
- 
                                    Body Width1.281 inches maximum 
- 
                                    Bushing Length0.380 inches maximum 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps300.0 ac all locations 
- 
                                    Test Data Document81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type 
- 
                                    ~1data on certain environmental and performanc 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Pole Quantity2 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.625 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations and 0.240 maximum at 400 pct all locations 
- 
                                    Mounting Surface To Terminal End Distance1.828 inches maximum 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and hermetically sealed 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac all locations 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Terminal Type And Quantity4 wire hook 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Case Materialmetal 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac all locations 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Body Length1.562 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.906 inches maximum 
- 
                                    Ultimate Trip Time Per Pole In Seconds0.200 minimum all locations and 7.000 maximum all locations 
- 
                                    Frequency In Hertz400.0 all locations 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    