Technical Characteristics
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Body Length6.000 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Unthreaded Mounting Hole Diameter0.188 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length5.125 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.375 inches nominal 
- 
                                    Pole Quantity3 
- 
                                    Maximum Continuous Load Current Rating Per Pole90.0 amperes ac and 90.0 amperes dc 
- 
                                    Circuit Protection Typeovercurrent 
- 
                                    Trip Release Methodthermal-magnetic 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Inclosure Protection Type For Which Designeddustproof 
- 
                                    Frequency In Hertz60.0 
- 
                                    Body Width4.125 inches nominal 
- 
                                    Body Height3.375 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length5.562 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.375 inches nominal 
- 
                                    Boss Height0.187 inches nominal 
- 
                                    Mounting Facility Type And Quantity5 unthreaded hole 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac and 250.0 dc 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps7500.0 ac and 5000.0 dc 
- 
                                    Trip Release Characteristictime delay 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current43.000 minimum at 200 pct and 120.000 maximum at 200 pct 
- 
                                    Trip Release Ambient Temp Rating40.0 deg celsius nominal 
- 
                                    Terminal Type And Quantity6 screw 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    