17-13936-5
Circuit Breakers
CIRCUIT BREAKER
17-13936-5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Switch Terminal Type
tab, solder lug
-
Center To Center Distance Between Terminals Parallel To Width
0.850 inches nominal
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac all locations and 2.0 amperes dc all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.560 inches nominal
-
Reset Method
manual
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations and 28.0 dc all locations
-
Switch Location And Position Designation
internal at pole three
-
Thread Series Designator
uns
-
Case Material
plastic
-
Trip Release Method
thermal all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac all locations and 2500.0 dc all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.341 inches nominal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 all locations
-
Internal Trip Release Configuration
series trip all locations
-
Body Height
2.765 inches maximum
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Nominal Thread Size
0.469 inches
-
Bushing Length
0.280 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.841 inches nominal
-
Frequency In Hertz
400.0 all locations
-
Body Width
0.850 inches maximum
-
Body Length
2.000 inches maximum
-
Terminal Type And Quantity
6 screw
-
Switch Current Rating And Type In Amps
7.0 ac and 4.0 dc
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Body Style
multipole-single actuator type
-
Switch Contact Arrangement
single pole, double throw
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Actuator Position Designation
at pole two
-
Switch Voltage Rating And Type In Volts
130.0 ac and 28.0 dc
-
Manual Actuator Type And Quantity
1 push-pull
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct all locations and 35.000 maximum at 200 pct all locations
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods