5003-3016
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
5003-3016
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Operating Current Rating Per Function In Amps
0.5 5th radio interference
 - 
                                    
Special Features
11 functions
 - 
                                    
Operating Current Rating Per Function In Amps
0.5 6th radio interference
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
1000.0 1st radio interference
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
 - 
                                    
Unthreaded Mounting Hole Diameter
0.196 inches nominal
 - 
                                    
Body Length
6.360 inches minimum and 6.400 inches maximum
 - 
                                    
Load Impedance Per Function
50.0 ohms 2nd radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
2.0 2nd radio interference
 - 
                                    
Style Designator
rectangular terminal/terminals on adjacent surfaces
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
1000.0 2nd radio interference
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
1000.0 3rd radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
 - 
                                    
Body Material
metal
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
 - 
                                    
Maximum Voltage Drop Per Function
100.0 millivolts ac 1st radio interference
 - 
                                    
Load Impedance Per Function
50.0 ohms 3rd radio interference
 - 
                                    
Overall Height
4.310 inches nominal
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
 - 
                                    
Overall Length
7.480 inches minimum and 7.520 inches maximum
 - 
                                    
Functional Terminal Type And Quantity
11 threaded stud output 2nd function
 - 
                                    
Maximum Voltage Drop Per Function
100.0 millivolts ac 3rd radio interference
 - 
                                    
Average Life Rating In Hours
1000.0
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
28.0 volts dc 2nd radio interference 2nd function
 - 
                                    
Maximum Voltage Drop Per Function
100.0 millivolts ac 4th radio interference
 - 
                                    
Overall Width
3.540 inches minimum and 3.580 inches maximum
 - 
                                    
Maximum Voltage Drop Per Function
100.0 millivolts dc 2nd radio interference
 - 
                                    
Load Impedance Per Function
50.0 ohms 4th radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
28.0 volts dc 5th radio interference 5th function
 - 
                                    
Operating Current Rating Per Function In Amps
10.0 1st radio interference
 - 
                                    
Input Terminal Manufacturer Code
96906
 - 
                                    
Test Data Document
97151-68d40003 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
 - 
                                    
Operating Voltage Rating And Type Per Function
28.0 volts dc 6th radio interference 6th function
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
 - 
                                    
Maximum Voltage Drop Per Function
100.0 millivolts dc 5th radio interference
 - 
                                    
Maximum Voltage Drop Per Function
100.0 millivolts dc 6th radio interference
 - 
                                    
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
 - 
                                    
Load Impedance Per Function
50.0 ohms 5th radio interference
 - 
                                    
Mounting Facility Type And Quantity
20 unthreaded hole
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.187 inches nominal
 - 
                                    
Body Width
2.420 inches minimum and 2.460 inches maximum
 - 
                                    
Load Impedance Per Function
50.0 ohms 6th radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
12.0 3rd radio interference
 - 
                                    
Load Impedance Per Function
50.0 ohms 1st radio interference
 - 
                                    
Functional Terminal Type And Quantity
2 connector, receptacle input 1st function and 1 connector, plug input 1st function
 - 
                                    
Operating Temp Range
-55.0/+85.0 deg celsius
 - 
                                    
Operating Voltage Rating And Type Per Function
115.0 volts ac 4th radio interference 4th function
 - 
                                    
Operating Current Rating Per Function In Amps
12.0 4th radio interference
 - 
                                    
Inclosure Type
encased
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.115 inches minimum and 7.135 inches maximum
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    