LS10159-2P
Circuit Breakers
CIRCUIT BREAKER
LS10159-2P
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current2.500 minimum at 200 pct all locations and 40.000 maximum at 200 pct all locations 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent145.0 all locations 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Bushing Length0.281 inches maximum 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Body Length1.094 inches maximum 
- 
                                    Manual Actuator Type And Quantity1 push-pull 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.735 inches maximum 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.780 inches nominal 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Terminal Type And Quantity6 screw 
- 
                                    Body Width2.350 inches maximum 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts120.0 ac all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 ac all locations 
- 
                                    Nominal Thread Size0.469 inches 
- 
                                    Body Height1.600 inches maximum 
- 
                                    Maximum Continuous Load Current Rating Per Pole2.5 amperes ac all locations 
- 
                                    Thread Series Designatoruns 
- 
                                    Case Materialplastic 
- 
                                    Trip Release Methodthermal all locations 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Reset Methodmanual 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    