AM3336HHHEMG6
Circuit Breakers
CIRCUIT BREAKER
AM3336HHHEMG6
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Inclosure Protection Type For Which Designed
moisture resistant and fungus resistant
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location
-
Case Material
plastic
-
Pole Quantity
4
-
Internal Trip Release Configuration
relay trip fourth location
-
Fragility Factor
moderately rugged
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac first location
-
Switch Terminal Type
tab, solder lug
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac second location
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Auxiliary Switch Function And Quantity
3 alarm
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc fourth location
-
Trip Release Characteristic
instantaneous all locations and time delay all locations
-
Switch Location And Position Designation
internal at pole two and internal at pole one and internal at pole three
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
8 threaded hole
-
Frequency In Hertz
60.0 first location
-
Frequency In Hertz
60.0 second location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Internal Trip Release Configuration
series trip first location
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Switch Contact Arrangement
single pole, double throw
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Terminal Type And Quantity
8 threaded stud
-
Internal Trip Release Configuration
series trip second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc fourth location
-
Internal Trip Release Configuration
series trip third location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac third location
-
Frequency In Hertz
60.0 third location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Body Width
2.990 inches minimum and 3.010 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
300.0 milliamperes dc fourth location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Manual Actuator Type And Quantity
4 toggle
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.500 minimum at 200 pct all locations and 7.000 maximum at 200 pct all locations
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods