10027442-101
Coils and Transformers
TRANSFORMER,POWER
10027442-101
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
2 single group
-
Mounting Hole Diameter
0.125 inches nominal single group
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Inclosure Type
fully inclosed
-
Mounting Method
unthreaded hole single group
-
Winding Operating Voltage
62.20 ac volts nominal single component 1st secondary
-
Terminal Type And Quantity
11 wire lead
-
Winding Operating Voltage
6.50 ac volts nominal single component single primary and 47.00 ac volts nominal single component single primary and 27.00 ac volts nominal single component single primary and 115.00 ac volts nominal single component single primary
-
Features Provided
color coded lead
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Body Width
1.400 inches maximum
-
Input-Output Phase Relationship
single phase to single phase single component
-
Distance Between Mounting Facility Centers
2.380 inches nominal single mounting facility single center group
-
Winding Operating Voltage
476.00 ac volts nominal single component 2nd secondary