2131970-12
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
2131970-12
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Overall Height
3.000 inches nominal
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
440.0 1st radio interference
 - 
                                    
Load Impedance Per Function
5.0 ohms 1st radio interference
 - 
                                    
Operating Temp Range
-55.0/+85.0 deg celsius
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
440.0 2nd radio interference
 - 
                                    
Functional Terminal Type And Quantity
4 wire lead output 2nd function
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
440.0 3rd radio interference
 - 
                                    
Overall Length
7.500 inches nominal
 - 
                                    
Power Line Frequency Rating Per Function In Hertz
440.0 4th radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
3.0 1st radio interference
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.250 inches nominal
 - 
                                    
Load Impedance Per Function
5.0 ohms 2nd radio interference
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
 - 
                                    
Load Impedance Per Function
5.0 ohms 3rd radio interference
 - 
                                    
Maximum Temp Rise
25.0 deg celsius
 - 
                                    
Load Impedance Per Function
5.0 ohms 4th radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
130.0 volts ac 3rd radio interference 3rd function
 - 
                                    
Source Impedance Rating Per Function
5.0 ohms 1st radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
3.0 2nd radio interference
 - 
                                    
Body Material
metal
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
 - 
                                    
Source Impedance Rating Per Function
5.0 ohms 2nd radio interference
 - 
                                    
Source Impedance Rating Per Function
5.0 ohms 3rd radio interference
 - 
                                    
Source Impedance Rating Per Function
5.0 ohms 4th radio interference
 - 
                                    
Operating Current Rating Per Function In Amps
3.0 3rd radio interference
 - 
                                    
Functional Terminal Type And Quantity
1 threaded stud ground 3rd function
 - 
                                    
Operating Current Rating Per Function In Amps
3.0 4th radio interference
 - 
                                    
Style Designator
rectangular terminal/terminals on opposite surfaces
 - 
                                    
Average Life Rating In Hours
10000.0
 - 
                                    
Body Width
3.000 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
6.870 inches nominal
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Maximum Voltage Drop Per Function
2.4 volts ac 1st radio interference
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
130.0 volts ac 4th radio interference 4th function
 - 
                                    
Unthreaded Mounting Hole Diameter
0.219 inches nominal
 - 
                                    
Maximum Voltage Drop Per Function
2.4 volts ac 2nd radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
130.0 volts ac 2nd radio interference 2nd function
 - 
                                    
Body Length
6.000 inches nominal
 - 
                                    
Maximum Dielectric Withstanding Ac Rms Voltage
260.0 volts at sea level
 - 
                                    
Maximum Voltage Drop Per Function
2.4 volts ac 3rd radio interference
 - 
                                    
Functional Terminal Type And Quantity
4 wire lead input 1st function
 - 
                                    
Maximum Voltage Drop Per Function
2.4 volts ac 4th radio interference
 - 
                                    
Operating Voltage Rating And Type Per Function
130.0 volts ac 1st radio interference 1st function
 - 
                                    
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
 - 
                                    
Inclosure Type
hermetically sealed
 