260-2342-000
Circuit Breakers
CIRCUIT BREAKER
260-2342-000
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Case Material
plastic
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Body Width
0.750 inches nominal
 - 
                                    
Terminal Type And Quantity
2 screw
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.375 inches nominal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
750.0 milliamperes ac single location and 750.0 milliamperes dc single location
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Unpackaged Unit Weight
1.250 ounces
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Reset Method
automatic
 - 
                                    
Unthreaded Mounting Hole Diameter
0.150 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.813 inches nominal
 - 
                                    
Pole Quantity
1
 - 
                                    
Mounting Surface To Terminal End Distance
0.938 inches nominal
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 100.000 maximum at 200 pct single location
 - 
                                    
Mounting Facility Type And Quantity
2 unthreaded hole
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Body Style
single pole type
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location
 - 
                                    
Overall Length
1.750 inches nominal
 - 
                                    
Frequency In Hertz
60.0 single location
 - 
                                    
Inclosure Protection Type For Which Designed
vibration resistant and dustproof and corrosion resistant and shock resistant
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location and 2000.0 dc single location
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    