MP-714
Circuit Breakers
CIRCUIT BREAKER
MP-714
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations and 20.0 amperes dc all locations
-
Body Style
multipole-multiple actuator type
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Mounting Facility Type And Quantity
3 threaded bushing
-
Mounting Surface To Terminal End Distance
1.813 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct all locations and 55.000 maximum at 200 pct all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Frequency In Hertz
400.0 all locations
-
Manual Actuator Type And Quantity
3 push-pull
-
Terminal Type And Quantity
6 tab w/screw
-
Bushing Length
0.235 inches minimum and 0.265 inches maximum
-
Body Length
2.235 inches minimum and 2.265 inches maximum
-
Nominal Thread Size
0.469 inches
-
Unpackaged Unit Weight
0.330 pounds
-
Thread Series Designator
uns
-
Case Material
plastic
-
Trip Release Method
thermal all locations
-
Fragility Factor
moderately rugged
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.450 inches minimum and 0.640 inches maximum
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Thread Quantity Per Inch
32
-
Body Width
2.407 inches minimum and 2.437 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations and 30.0 dc all locations
-
Internal Trip Release Configuration
series trip all locations
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Test Data Document
76374-mp-714 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations and 6000.0 dc all locations
Related Parts by Category
Related Parts by Manufacturer
Certified toAS6081 Methods