QP2020
Circuit Breakers
CIRCUIT BREAKER
QP2020
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Trip Release Characteristic
instantaneous and time delay
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
between pole one and two
 - 
                                    
Trip Release Ambient Temp Rating
50.0 deg celsius nominal
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Body Length
3.000 inches nominal
 - 
                                    
Body Width
2.000 inches nominal
 - 
                                    
Body Height
2.375 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Boss Height
0.187 inches nominal
 - 
                                    
Pole Quantity
2
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac
 - 
                                    
Trip Release Method
thermal-magnetic
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
13.000 minimum at 200 pct and 110.000 maximum at 200 pct
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant
 - 
                                    
Frequency In Hertz
60.0
 - 
                                    
Terminal Type And Quantity
2 clip and 2 compression
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.000 inches nominal
 - 
                                    
Mounting Facility Type And Quantity
4 terminal
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac
 - 
                                    
Circuit Protection Type
overcurrent
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    


