44-100P50-2-5
Circuit Breakers
CIRCUIT BREAKER
44-100P50-2-5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Thread Series Designator
uns
 - 
                                    
Inclosure Protection Type For Which Designed
general purpose
 - 
                                    
Nominal Thread Size
0.375 inches
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Manual Actuator Type And Quantity
1 push button
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Reset Method
manual
 - 
                                    
Trip Release Characteristic
time delay
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac and 24.0 dc
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac and 15.0 amperes dc
 - 
                                    
Thread Quantity Per Inch
27
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Body Length
0.765 inches maximum
 - 
                                    
Bushing Length
0.393 inches nominal
 - 
                                    
Terminal Type And Quantity
2 quick disconnect,male
 - 
                                    
Frequency In Hertz
60.0
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius maximum
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
13.000 minimum at 200 pct and 45.000 maximum at 200 pct
 - 
                                    
Internal Trip Release Configuration
series trip
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0
 - 
                                    
Trip Release Method
thermal
 - 
                                    
Circuit Protection Type
overcurrent
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15.0 ac and 15.0 dc
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing
 - 
                                    
Pole Quantity
1
 - 
                                    
Mounting Surface To Terminal End Distance
1.922 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.500 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Body Width
0.460 inches maximum
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    