484653-12
Circuit Breakers
CIRCUIT BREAKER
484653-12
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations
 - 
                                    
~1
0 pct all locations
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Boss Height
0.219 inches nominal
 - 
                                    
Unthreaded Mounting Hole Diameter
0.562 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
7.875 inches nominal
 - 
                                    
Body Height
3.812 inches nominal
 - 
                                    
Body Length
9.375 inches nominal
 - 
                                    
Body Style
9b multipole-single actuator type
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Trip Release Method
thermal-magnetic all locations
 - 
                                    
Trip Release Characteristic
instantaneous and time delay all locations
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
 - 
                                    
Reset Method
manual
 - 
                                    
Body Width
4.125 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.500 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
 - 
                                    
Pole Quantity
3
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
250.000 nominal at 125 pct and 5.000 nominal at 200 pct and 10.000 nominal at 30
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant
 - 
                                    
Trip Release Ambient Temp Rating
40.0 deg celsius nominal all locations
 - 
                                    
Frequency In Hertz
60.0
 - 
                                    
Terminal Type And Quantity
6 screw
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    


