34047
Switches
SWITCH,ROTARY
34047
SWITCH,ROTARY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Overall Length
3.780 inches nominal
 - 
                                    
First Flat Length
0.440 inches nominal single actuator
 - 
                                    
Individual Section Quantity
5
 - 
                                    
Mounting Method
threaded bushing single mounting facility
 - 
                                    
Nominal Thread Size
0.375 inches single mounting facility
 - 
                                    
Contact Voltage Rating In Volts
115.0
 - 
                                    
Contact Voltage Rating In Volts
28.0
 - 
                                    
Shaft Flat/Slot Angular Location
0.0 degrees from nonturn device single actuator
 - 
                                    
Rotor Through Connection Quantity
1 each section
 - 
                                    
Switch Actuator Indexing Position Quantity
8 single actuator
 - 
                                    
Contact Switching Action
breaks before makes each section rear
 - 
                                    
Switch Actuator Positioning Increment
45.0 degrees single actuator
 - 
                                    
Detent Rotational Torque Range
+16.0/+96.0 inch-pounds (pound-inches) single actuator
 - 
                                    
Thread Series Designator
unef single mounting facility
 - 
                                    
Thread Class
2a single mounting facility
 - 
                                    
Thread Length
0.380 inches nominal single mounting facility
 - 
                                    
Hazardous Locations/Environmental Protection
moisture resistant
 - 
                                    
Flat Height
0.216 inches nominal single actuator
 - 
                                    
Shaft Diameter
0.247 inches nominal single actuator
 - 
                                    
Shaft Length
0.620 inches nominal single actuator
 - 
                                    
Nonturn Device Radius
0.375 inches nominal at 6:00 o'clock
 - 
                                    
Nonturn Device Type
pin at 6:00 o'clock
 - 
                                    
Switch Contact Basic Design
nonpile-up symmetrical
 - 
                                    
Pole Quantity
1 each section front
 - 
                                    
Throw Quantity
8 each section rear
 - 
                                    
Shaft Type
round, slotted, flatted single actuator
 - 
                                    
Terminal Type
tab, solder lug
 - 
                                    
Switch Actuator Stop Device Type
fixed stop single actuator
 - 
                                    
~1
ating at sea level
 - 
                                    
Contact Load Current Rating
10.0 amperes resistive load dc at sea level
 - 
                                    
Contact Load Current Rating
15.0 amperes resistive load and 10.0 amperes inductive load highest ac voltage r
 - 
                                    
Style Designator
9 tap, circular, bushing mount
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    