Technical Characteristics
- 
                                    
Frequency In Hertz
400.0 all locations
 - 
                                    
Mounting Surface To Terminal End Distance
1.797 inches minimum and 1.828 inches maximum
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations
 - 
                                    
Body Width
1.250 inches minimum and 1.281 inches maximum
 - 
                                    
~1
type data on certain environmental and performa
 - 
                                    
Test Data Document
81349-mil-prf-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Pole Quantity
2
 - 
                                    
Bushing Length
0.332 inches minimum and 0.380 inches maximum
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Reset Method
manual
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Trip Release Characteristic
time delay all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
12.5 amperes ac all locations and 12.5 amperes dc all locations
 - 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and 0.906 inches maximum
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 50.0 dc all locations
 - 
                                    
Nominal Thread Size
0.375 inches
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Body Length
1.531 inches minimum and 1.562 inches maximum
 - 
                                    
Trip Release Method
magnetic all locations
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
 - 
                                    
Terminal Type And Quantity
4 wire hook
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Case Material
metal
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Position Designation
between pole one and two
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Specification/Standard Data
81349-mil-prf-39019/3 government specification
 - 
                                    
Unpackaged Unit Weight
100.0 grams
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    