SM-B-185207-1
Circuit Breakers
CIRCUIT BREAKER
SM-B-185207-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Boss Height
0.208 inches minimum and 0.228 inches maximum
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Mounting Facility Type And Quantity
4 threaded hole and 4 unthreaded hole
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.350 minimum at 200 pct single location and 1.000 maximum at 200 pct single location
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Body Height
2.678 inches minimum and 2.698 inches maximum
 - 
                                    
Pole Quantity
1
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Body Width
1.490 inches minimum and 1.510 inches maximum
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
 - 
                                    
Inclosure Protection Type For Which Designed
dustproof and fungus proof
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
 - 
                                    
Nominal Thread Size
0.164 inches
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.974 inches minimum and 0.994 inches maximum
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.349 inches minimum and 4.369 inches maximum
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Reset Method
manual
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
4.349 inches minimum and 4.369 inches maximum
 - 
                                    
Body Style
single pole type
 - 
                                    
Trip Release Method
magnetic-hydraulic single location
 - 
                                    
Frequency In Hertz
60.0 single location
 - 
                                    
Body Length
5.240 inches minimum and 5.260 inches maximum
 - 
                                    
Unthreaded Mounting Hole Diameter
0.190 inches nominal
 - 
                                    
Terminal Type And Quantity
2 compression
 - 
                                    
Case Material
plastic
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    