2263SMG4-65-120VAC60C1
Circuit Breakers
CIRCUIT BREAKER
2263SMG4-65-120VAC60C1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Unpackaged Unit Weight
1.250 pounds
 - 
                                    
Unthreaded Mounting Hole Diameter
0.190 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.359 inches nominal
 - 
                                    
Boss Height
0.218 inches nominal
 - 
                                    
Pole Quantity
2
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Circuit Protection Type
overcurrent
 - 
                                    
Ultimate Trip Time Per Pole In Seconds
170.000 minimum and 600.000 maximum
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Internal Trip Release Configuration
series trip
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 minimum at 200 pct and 125.000 maximum at 200 pct
 - 
                                    
Frequency In Hertz
60.0
 - 
                                    
Body Length
5.250 inches nominal
 - 
                                    
Body Width
2.000 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
4.359 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
0.984 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
any acceptable
 - 
                                    
Mounting Surface To Terminal End Distance
2.687 inches nominal
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Mounting Facility Type And Quantity
2 unthreaded hole
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
65.0 amperes ac
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac
 - 
                                    
Trip Release Method
magnetic-hydraulic
 - 
                                    
Trip Release Characteristic
time delay
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
 - 
                                    
Reset Method
manual
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Position Designation
between pole one and two
 - 
                                    
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant and moisture resistant
 - 
                                    
Terminal Type And Quantity
4 threaded stud
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    


