30055-30STK
Circuit Breakers
CIRCUIT BREAKER
30055-30STK
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Overall Length50.8 millimeters nominal 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 dc single location 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length39.62 millimeters nominal 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Mounting Surface To Terminal End Distance34.97 millimeters nominal 
- 
                                    Inclosure Protection Type For Which Designedhermetically sealed 
- 
                                    Pole Quantity1 
- 
                                    Case Materialmetal 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Maximum Continuous Load Current Rating Per Pole30.0 amperes dc single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts12.0 dc single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Body Width19.81 millimeters nominal 
- 
                                    Mounting Facility Type And Quantity2 terminal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length17.14 millimeters minimum and 17.27 millimeters maximum 
- 
                                    Trip Release Characteristicinstantaneous single location 
- 
                                    Reset Methodautomatic 
- 
                                    Terminal Type And Quantity2 threaded stud 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    