ALB5-50A
Circuit Breakers
CIRCUIT BREAKER
ALB5-50A
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
~1
data on certain environmental and performanc
 - 
                                    
Mounting Facility Type And Quantity
2 threaded stud
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.125 inches nominal
 - 
                                    
Inclosure Protection Type For Which Designed
shockproof and vibrationproof
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 125 pct all locations and 100.000 maximum at 125 pct all locations
 - 
                                    
Boss Height
0.125 inches nominal
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac all locations and 125.0 dc all locations
 - 
                                    
Thread Quantity Per Inch
24
 - 
                                    
Terminal Type And Quantity
6 quick disconnect, male
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
2.625 inches nominal
 - 
                                    
Body Height
3.375 inches nominal
 - 
                                    
Body Length
4.125 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Ultimate Trip Time Per Pole In Seconds
3600.000 nominal all locations
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.500 inches nominal
 - 
                                    
Pole Quantity
3
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations and 5000.0 dc all locations
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Reset Method
manual
 - 
                                    
Nominal Thread Size
0.216 inches
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Body Width
3.344 inches nominal
 - 
                                    
External Actuator Linkage Arrangement
one, two, and three linked
 - 
                                    
Trip Release Characteristic
instantaneous all locations and time delay all locations
 - 
                                    
Trip Release Method
thermal-magnetic all locations
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Trip Release Ambient Temp Rating
50.0 deg celsius nominal all locations
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.937 inches nominal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations and 50.0 amperes dc all locations
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Test Data Document