Technical Characteristics
- 
                                    
Longest Vertical Distance Between Mounting Centers
1.500 inches nominal single mounting facility
 - 
                                    
Overall Width
2.250 inches maximum
 - 
                                    
Thread Class
2b single mounting facility
 - 
                                    
Pole Quantity
1 each section front
 - 
                                    
Individual Section Quantity
2
 - 
                                    
Operating Temp Range
-55.0/+85.0 deg celsius
 - 
                                    
Throw Quantity
24 each section rear
 - 
                                    
Mounting Method
threaded hole single mounting facility and bracket single mounting facility and unthreaded hole single mounting facility
 - 
                                    
Switch Actuator Indexing Position Quantity
24 single actuator
 - 
                                    
Shortest Horizontal Distance Between Mounting Centers
0.750 inches nominal single mounting facility
 - 
                                    
Contact Voltage Rating In Volts
115.0 ac at sea level
 - 
                                    
Contact Switching Action
breaks before makes each section rear
 - 
                                    
Switch Actuator Positioning Increment
15.0 degrees single actuator
 - 
                                    
Terminal Type
turret
 - 
                                    
Precious Material
silver
 - 
                                    
Overall Height
2.250 inches maximum
 - 
                                    
Shaft Type
round single actuator
 - 
                                    
Unthreaded Mounting Hole Diameter
0.168 inches minimum single mounting facility and 0.174 inches maximum single mounting facility
 - 
                                    
Shaft Length
1.125 inches nominal single actuator
 - 
                                    
Style Designator
tap, square frame
 - 
                                    
Shortest Vertical Distance Between Mounting Centers
0.750 inches nominal single mounting facility
 - 
                                    
Nominal Thread Size
0.164 inches single mounting facility
 - 
                                    
Contact Load Current Rating
5.0 amperes resistive load ac at sea level
 - 
                                    
Thread Quantity Per Inch
32 single mounting facility
 - 
                                    
Shaft Diameter
0.249 inches minimum single actuator and 0.250 inches maximum single actuator
 - 
                                    
Overall Length
4.625 inches nominal
 - 
                                    
Mounting Facility Pattern
four position diamond single mounting facility
 - 
                                    
Switch Contact Basic Design
nonpile-up symmetrical
 - 
                                    
Precious Material And Location
contacts and terminals silver
 - 
                                    
Rotor Through Connection Quantity
1 each section
 - 
                                    
Longest Horizontal Distance Between Mounting Centers
1.500 inches nominal single mounting facility
 - 
                                    
Thread Series Designator
unc single mounting facility
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    