260-4062-030
Circuit Breakers
CIRCUIT BREAKER
260-4062-030
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Thread Pitch Diameters
+0.3503/+0.3537 inches
 - 
                                    
Nominal Thread Size
0.375 inches
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
 - 
                                    
Body Length
1.448 inches minimum and 1.510 inches maximum
 - 
                                    
Trip Release Method
magnetic-hydraulic all locations
 - 
                                    
Terminal Type And Quantity
4 wire hook
 - 
                                    
Bushing Length
0.360 inches minimum and 0.380 inches maximum
 - 
                                    
Case Material
metal
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Position Designation
between pole one and two
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Body Style
single pole type
 - 
                                    
Frequency In Hertz
400.0 all locations
 - 
                                    
Thread Series Designator
unef
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.870 inches minimum and 0.880 inches maximum
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct all locations and 14.000 maximum at 200 pct all locations
 - 
                                    
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant and hermetically sealed
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Unpackaged Unit Weight
3.400 ounces
 - 
                                    
Mounting Surface To Terminal End Distance
1.524 inches minimum and 1.586 inches maximum
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Body Width
0.567 inches minimum and 0.629 inches maximum
 - 
                                    
Pole Quantity
2
 - 
                                    
Reset Method
manual
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
1.5 amperes ac all locations
 - 
                                    
Trip Release Characteristic
time delay all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Ultimate Trip Time Per Pole In Seconds
6.500 minimum all locations and 30.000 maximum all locations
 