F2070
Circuit Breakers
CIRCUIT BREAKER
F2070
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Trip Release Characteristic
instantaneous all locations
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.369 inches minimum and 1.369 inches maximum
 - 
                                    
Pole Quantity
2
 - 
                                    
Reset Method
manual
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Trip Release Ambient Temp Rating
40.0 deg celsius nominal all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.495 inches minimum and 4.505 inches maximum
 - 
                                    
Boss Height
0.120 inches minimum and 0.130 inches maximum
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations and 250.0 dc all locations
 - 
                                    
Body Height
3.807 inches minimum and 3.817 inches maximum
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
 - 
                                    
Trip Release Method
thermal-magnetic all locations
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
7.245 inches minimum and 7.255 inches maximum
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
70.0 amperes ac all locations and 70.0 amperes dc all locations
 - 
                                    
Arc Quenching Method
deion
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Terminal Type And Quantity
6 compression
 - 
                                    
Mounting Facility Type And Quantity
2 unthreaded hole
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Inclosure Protection Type For Which Designed
general purpose
 - 
                                    
Body Width
4.120 inches minimum and 4.130 inches maximum
 - 
                                    
Unthreaded Mounting Hole Diameter
0.276 inches minimum and 0.286 inches maximum
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.369 inches minimum and 1.379 inches maximum
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations and 10000.0 dc all locations
 - 
                                    
Body Length
9.370 inches minimum and 9.380 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Ultimate Trip Time Per Pole In Seconds
400.000 nominal all locations
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    