3XAM1516MG3-50-208VAC400-12
Circuit Breakers
CIRCUIT BREAKER
3XAM1516MG3-50-208VAC400-12
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Operating Voltage Type And Rating Per Pole In Volts208.0 ac all locations 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole50.0 amperes ac all locations 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current4.000 minimum at 200 pct all locations and 10.500 maximum at 200 pct all locations 
- 
                                    Thread Series Designatorunc 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Body Length3.719 inches nominal 
- 
                                    Mounting Surface To Terminal End Distance3.239 inches nominal 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    External Actuator Linkage Arrangementone, two, and three linked 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.031 inches nominal 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Center To Center Distance Between Terminals Parallel To Length3.063 inches nominal 
- 
                                    Body Width3.052 inches nominal 
- 
                                    Mounting Facility Type And Quantity6 threaded hole 
- 
                                    Inclosure Protection Type For Which Designedmoisture resistant and fungus resistant and explosion resistant 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 all locations 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Boss Height0.156 inches nominal 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1500.0 ac all locations 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.750 inches nominal 
- 
                                    Manual Actuator Type And Quantity3 toggle 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.031 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Terminal Type And Quantity6 threaded stud 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    