AP1-59-5
Circuit Breakers
CIRCUIT BREAKER
AP1-59-5
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Method
magnetic single location
-
Terminal Type And Quantity
2 wire hook
-
Body Width
0.625 inches nominal
-
Mounting Surface To Terminal End Distance
1.281 inches nominal
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Pole Quantity
1
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Center To Center Distance Between Terminals Parallel To Length
0.719 inches nominal
-
Body Length
1.484 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location
-
Bushing Length
0.375 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
-
Trip Release Characteristic
time delay single location
-
Body Style
single pole type
-
Frequency In Hertz
60.0 single location
-
Thread Series Designator
unef
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.950 minimum at 200 pct single location and 4.500 maximum at 200 pct single location
Related Parts by Category
Related Parts by Manufacturer


AS6081 Methods