D7271-8-3

Circuit Breakers

CIRCUIT BREAKER

D7271-8-3

5925-00-769-3469

5925 - Circuit Breakers

B-N Group Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.750 inches maximum

  • Body Length

    1.375 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct single location and 70.000 maximum at 200 pct single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location and 3.0 amperes dc single location

  • Unpackaged Unit Weight

    1.500 ounces

  • Mounting Surface To Terminal End Distance

    1.313 inches nominal

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Bushing Length

    0.344 inches nominal

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Inclosure Protection Type For Which Designed

    sand resistant and dusttight and shock resistant and vibration resistant and corrosion resistant and explosion proof

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location and 4000.0 dc single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...