ETN1004
Circuit Breakers
CIRCUIT BREAKER
ETN1004
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 ac all locations and 2500.0 dc all locations 
- 
                                    Case Materialplastic 
- 
                                    Body Length4.125 inches nominal 
- 
                                    Body Height3.375 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length2.625 inches nominal 
- 
                                    Maximum Continuous Load Current Rating Per Pole25.0 amperes ac all locations and 25.0 amperes dc all locations 
- 
                                    Thread Quantity Per Inch24 
- 
                                    Boss Height0.125 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.125 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width2.938 inches nominal 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length0.625 inches nominal 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Terminal Type And Quantity6 quick disconnect, female 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Trip Release Ambient Temp Rating50.0 deg celsius nominal all locations 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Trip Release Methodthermal-magnetic all locations 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current20.000 minimum at 200 pct all locations and 90.000 maximum at 200 pct all locations 
- 
                                    Trip Release Characteristicinstantaneous all locations and time delay all locations 
- 
                                    Body Width3.344 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Nominal Thread Size0.216 inches 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts500.0 ac all locations and 250.0 dc all locations 
- 
                                    Reset Methodmanual 
- 
                                    Thread Series Designatorunc 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Pole Quantity3 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    