MIL-C-7079
Circuit Breakers
CIRCUIT BREAKER
MIL-C-7079
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Mounting Surface To Terminal End Distance
2.000 inches maximum
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Inclosure Protection Type For Which Designed
explosion resistant and corrosion resistant
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc single location
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct all locations and 50.000 maximum at 200 pct all locations
 - 
                                    
Reset Method
manual
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
 - 
                                    
~1
data on certain environmental and performance
 - 
                                    
Test Data Document
81349-mil-c-7079 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Bushing Length
0.250 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
 - 
                                    
Body Width
0.750 inches maximum
 - 
                                    
Specification/Standard Data
96906-ms24506 government standard
 - 
                                    
Terminal Type And Quantity
2 tab w/screw
 - 
                                    
Ultimate Trip Time Per Pole In Seconds
60.000 maximum single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
 - 
                                    
Body Style
single pole type
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 dc single location
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Body Length
2.189 inches maximum
 - 
                                    
Pole Quantity
1
 - 
                                    
Main Contact Tripping Mechanism Type
nontrip free
 - 
                                    
Manual Actuator Type And Quantity
1 push-pull
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
1.188 inches nominal
 - 
                                    
Circuit Protection Type
overcurrent single location
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    