TE122070

Circuit Breakers

CIRCUIT BREAKER

TE122070

5925-00-810-4913

5925 - Circuit Breakers

General Electric Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Mounting Facility Type And Quantity

    4 slot

  • Pole Quantity

    2

  • Reset Method

    manual

  • Body Length

    6.310 inches nominal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Body Width

    2.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.380 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Boss Height

    0.187 inches nominal

  • Body Style

    multipole-single actuator type

  • Terminal Type And Quantity

    4 compression

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.880 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac all locations and 70.0 amperes dc all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Slot Width

    0.190 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Height

    3.567 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations and 5000.0 dc all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 minimum at 200 pct all locations and 90.000 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.560 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 250.0 dc all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...