1053032-1
Circuit Breakers
CIRCUIT BREAKER
1053032-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Pole Quantity
2
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Reset Method
manual
 - 
                                    
Boss Height
0.208 inches minimum and 0.228 inches maximum
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.052 inches minimum and 3.072 inches maximum
 - 
                                    
Trip Release Characteristic
time delay all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Body Height
2.677 inches minimum and 2.697 inches maximum
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Trip Release Method
magnetic-hydraulic all locations
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
0.990 inches minimum and 1.010 inches maximum
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Inclosure Protection Type For Which Designed
dustproof and fungus proof
 - 
                                    
Actuator Position Designation
between pole one and two
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Nominal Thread Size
0.164 inches
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
4.349 inches minimum and 4.369 inches maximum
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
 - 
                                    
Body Length
5.240 inches minimum and 5.260 inches maximum
 - 
                                    
Unthreaded Mounting Hole Diameter
0.190 inches nominal
 - 
                                    
Terminal Type And Quantity
4 threaded stud
 - 
                                    
Body Width
1.990 inches minimum and 2.010 inches maximum
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.320 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations
 - 
                                    
Mounting Facility Type And Quantity
4 threaded hole and 2 unthreaded hole
 - 
                                    
Case Material
plastic
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.974 inches minimum and 0.994 inches maximum
 - 
                                    
Fragility Factor
moderately rugged
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    