972.55.17.504

Circuit Breakers

CIRCUIT BREAKER

972.55.17.504

5925-00-835-4431

5925 - Circuit Breakers

Pilatus Aircraft Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    trip-reset

  • Unpackaged Unit Weight

    1.500 ounces

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.937 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • ~1

    data on certain environmental and performance

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    shockproof and moisture resistant and corrosion resistant and dusttight and explosion proof and sand resistant and vibration resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Bushing Length

    0.313 inches minimum and 0.375 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 70.000 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.750 inches maximum

  • Specification/standard Data

    96906-ms24510 government standard

  • Body Length

    1.375 inches maximum

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    43500.0 ac all locations and 3500.0 dc all locations

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...