Technical Characteristics
- 
                                    Terminal Type And Quantity7 wire lead 
- 
                                    Body Length0.469 inches maximum 
- 
                                    Inclosure Typeopen 
- 
                                    Winding Operating Current2.0 milliamperes maximum of standard range b and better drop siding single component single primary 
- 
                                    Winding Function And Quantity1 primary single component and 1 secondary single component 
- 
                                    Body Outside Diameter0.344 inches maximum 
- 
                                    Hazardous Locations/Environmental Protectionmoisture resistant and vibration resistant 
- 
                                    Unpackaged Unit Weight (Non-Core)3.0 grams 
- 
                                    Maximum Transformer Power Rating100.0 milliwatts single component 
- 
                                    Impedance Rating In Ohms5000.0 nominal single component single primary 
- 
                                    Impedance Rating In Ohms10000.0 nominal single component single secondary 
- 
                                    Maximum Operating Temp105.0 deg celsius 
- 
                                    Frequency Response Tolerance In Decibels (Non-Core)-3.0/+3.0 single component 
- 
                                    Winding Shielding Methodinternal shield brought out to terminal single component 
- 
                                    Reliability Indicatornot established 
- 
                                    Mounting Methodterminal single group 
- 
                                    Frequency Rating300.0 hertz minimum single component and 20.0 kilohertz maximum single component 
- 
                                    Primary To Secondary Turn Ratio0.706 to 1 single component 
- 
                                    Winding Tap Location (Non-Core)center tap single component single primary 
- 
                                    Features Providedcolor coded lead and tinned wire leads 
- 
                                    Winding Tap Location (Non-Core)center tap single component single secondary 
Related Parts by Category
Related Parts by Manufacturer
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    