160-001-70

Circuit Breakers

CIRCUIT BREAKER

160-001-70

5925-00-844-9475

5925 - Circuit Breakers

Associated Aircraft Supply Co.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location and 6000.0 dc single location

  • Body Style

    single pole type

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.750 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.470 inches nominal

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Bushing Length

    0.250 inches nominal

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Unpackaged Unit Weight

    113.0 grams

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 65.000 maximum at 200 pct single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Overall Length

    2.189 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.862 inches nominal

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Body Length

    3.015 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Mounting Surface To Terminal End Distance

    2.250 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac single location and 70.0 amperes dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...