417137-22
Coils and Transformers
TRANSFORMER,AUDIO FREQUENCY
417137-22
TRANSFORMER,AUDIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Test Data Document
07690-417137 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
 - 
                                    
Primary To Secondary Turn Ratio
1 to 1-1/10 single component
 - 
                                    
Impedance Rating In Ohms
600.0 nominal single component single secondary
 - 
                                    
Frequency Rating
300.0 hertz minimum single component and 50.0 kilohertz maximum single component
 - 
                                    
Inclosure Type
fully inclosed
 - 
                                    
Winding Function And Quantity
1 primary single component and 1 secondary single component
 - 
                                    
Maximum Transformer Power Rating
50.0 milliwatts single component
 - 
                                    
Winding Operating Current
3.0 milliamperes maximum of standard range b and better drop siding single component single primary
 - 
                                    
Body Height
0.475 inches maximum
 - 
                                    
Terminal Type And Quantity
5 wire lead
 - 
                                    
Impedance Rating In Ohms
500.0 nominal single component single primary
 - 
                                    
Reliability Indicator
not established
 - 
                                    
Body Length
0.410 inches maximum
 - 
                                    
Mounting Method
terminal single group
 - 
                                    
Frequency Response Tolerance In Decibels (Non-Core)
-2.0/+2.0 single component
 - 
                                    
Maximum Operating Temp
130.0 deg celsius
 - 
                                    
Transformer Function
line
 - 
                                    
Winding Tap Location (Non-Core)
center tap single component single primary
 - 
                                    
Body Width
0.310 inches maximum
 
Related Parts by Category
Related Parts by Manufacturer
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    